SATEC PM296 ÇÁ·ÎÅäÄÝ

 

1. Àб⠼³Á¤

 

<±×¸² 1>Àº À̽º¶ó¿¤ SATAC»çÀÇ Power Meter PM296À» »ç¿ëÇÒ ¶§ÀÇ Åë½Å¼³Á¤ ¿¹ÀÌ´Ù.

 

             <±×¸² 1> SATEC PM296 ÇÁ·ÎÅäÄÝ Åë½Å¼³Á¤ ¿¹

 

<±×¸² 1>ÀÇ DEVICE ¼³Á¤Àº ¿¬°áµÈ Åë½ÅÆ÷Æ®(COM1), Åë½Å¼Óµµ( 9600 ), Parity Bit ( 0 ), Data Bit ( 8 ), Stop Bit ( 1 ), ¼øÀ¸·Î ÀÔ·ÂÇϴµ¥ 485Åë½Å Conveter¿¡ µû¶ó TxRTS(TxDTR), RxECHO ¹× TxRTS(TxDTR) End/Start Delay ½Ã°£(nSec)À» ÀÔ·ÂÇÑ´Ù.

SATEC RPT091ÀÇ Åë½Å¼Óµµ, Parity, Data, Stop Bit ´Â RDM¿¡ ¿¬°áÇÏ´Â Á¶ÀÛÆÇ³Ú À̳ª ¾Æ³¯·Î±×(µðÁöÅÐ) ¾²±â·Î º¯°æÇÒ ¼ö ÀÖ´Ù.

 

Âü°í) SATEC PM296 Åë½Å µå¶óÀ̺ê´Â MODBUS Çü½ÄÀÇ ÇÁ·ÎÅäÄÝÀ» »ç¿ëÇÑ´Ù.

 

 

Àб⠼³Á¤ ¹æ¹ý

 

READ ½ºÅ×ÀÌ¼Ç ÀÐÀ» Á¾·ù  ÀÐÀ» ½ÃÀÛ
ÁÖ¼Ò
 
¸Þ¸ð¸®
ÀúÀåÀ§Ä¡
Àд °¹¼ö(°íÁ¤)
READ, 1, DATA, 0, 0, 53,
READ, 1, SETUP, 0, 60, 15,
READ, 1, COMM, 0, 80, 6,

 

 

1)      ½ºÅ×ÀÌ¼Ç : RPT091 Meter ÀÇ ½ºÅ×ÀÌ¼Ç (ID) ¹øÈ£. (1 ~ 247)

2)      ÀÐÀ» Á¾·ù : ÀÐÀ» µ¥ÀÌÅÍ Á¾·ù¸¦ ÁöÁ¤.

DATA – Basic Data Àбâ,

ALARM - Alarm Setpoint Àбâ,

AO_EXP – Analog Output Expander Setup Àбâ,

AO_SET - Analog Output Setup Àбâ,

ASR - Alarm Status Register Àбâ,

COMM1 – Comm1 Communication Parameter Àбâ,

COMM2 – Comm2 Communication Parameter Àбâ,

DATA_LC - Data Log(Circular Access) Àбâ,

DATA_LS - Data Log(Sequential Access) Àбâ,

DATA_SET - Data Log Setup Àбâ,

DEFINE – User-Defined Data Àбâ,

DI – Digital Inputs Allocation Àбâ,

DIRECT – Direct MODBUS µ¥ÀÌÅÍ Àбâ(Àý´ë MODBUS ¹øÁö¸¦ ÀÐÀ½),

ESR – Extended Status Register Àбâ,

EVENT_LC - Event Log(Circular Access) Àбâ,

EVENT_LS - Event Log(Sequential Access) Àбâ,

EXTEND - Extend Data Àбâ, Extend ¿µ¿ªº°·Î ±¸ºÐ(0~60 : <Ç¥ 2>ÂüÁ¶),

SETUP – Basic Setup Àбâ,

LOG_MEM - Log Memory Partitions Setup Àбâ,

LOG_SET – Data Log Setup Àбâ,

MAP – User Definable Register Àбâ,

MEM_PAT - Memory Partitions Status/Control Àбâ,

MEM_STS - Memory Allocation Status Àбâ,

P_COUNT - Pulse Counters Setup Àбâ,

PULSE – Pulsing Setpoint Àбâ,

RELAY – Relay Status Àбâ,

RTC – RTC(Current Time) Àбâ,

STATUS – Instrument Status Àбâ,

TIMERS - Timers Setup Àбâ,

USER_OP - User Selectable Option Àбâ.

3)      ÀÐÀ» ½ÃÀÛÁÖ¼Ò : ÀÐÀ» Á¾·ùº° Àб⠽ÃÀÛ¹øÁö.

4) ¸Þ¸ð¸® ÀúÀå À§Ä¡ : Àоî¿Â »óÅ °ªÀ» ÀúÀåÇÒ ¹öÆÛÀ§Ä¡.

5) Àд ũ±â :    ÀÐÀ» Å©±â.

°¢ ÀÐÀ» Á¾·ù¿¡ µû¶ó Àбâ ÃÖ´ëÅ©±â°¡ ´Ù¸§. (<Ç¥ 1> ÂüÁ¶)

 

 

ÀÐÀ» Á¾·ù

ÃÖ´ë Å©±â

DATA

53

ALARM

125 (ÃÑ 704)

AO_EXP

48

AO_SET

6

ASR

12

COMM1

7

COMM2

7

DATA_LC

125 (ÃÑ 672)

DATA_LS

125 (ÃÑ 3200)

DATA_SET

125 (ÃÑ 256)

DEFINE

120

DI

5

DIRECT

MODBUS address ¿¡ µû¶ó ´Ù¸§.

ESR

34

EVENT_LC

120

EVENT_LS

120

EXTEND

Extend ¿µ¿ª¿¡ µû¶ó ´Ù¸§ (0~60 : <Ç¥ 2>ÂüÁ¶)

SETUP

18

LOG_MEM

125 (ÃÑ 152)

LOG_SET

16

MAP

120

MEM_PAT

125 (ÃÑ 768)

MEM_STS

48

P_COUNT

32

PULSE

12

RELAY

6

RTC

7

STATUS

8

TIMERS

4

USER_OP

8

<Ç¥ 1> ÀÐÀ» Á¾·ù¿¡ µû¸¥ Àбâ ÃÖ´ëÅ©±â

 

 

°íÀ¯ ¹øÈ£

µ¥ÀÌÅÍ ³»¿ë

ÃÖ´ë Å©±â

0

Real Time Values Per Phase

33

1

None

1

2

User Event Flags

8

3

Status Inputs

12

4

Relays

6

5

Pulse Counters

32

6

Real Time Values Per Phase

33

7

Real Time Low Values on Any Phase

12

8

Real Time High Values on Any Phase

12

9

Real Time Total Values

13

10

Real Time Auxiliary Values

6

11

Average Values Per Phase

33

12

Average Low Values on Any Phase

12

13

Average High Values on Any Phase

12

14

Average Total Values

13

15

Average Auxiliary Values

6

16

Present Demands

32

17

Total Energies

22

18

L1 ~ L3 Voltage, L1 ~ L3 Current Harmonics

260

19 ~ 21

L1 ~ L3 Voltage Odd Harmonics

20

22 ~ 24

L1 ~ L3 Current Odd Harmonics

20

25 ~ 27

Total KW, Total Kvar, Total PF Odd Harmonics

20

28

Minimum Real Time Values Per Phase

33

29

Minimum Real Time Total Values

6

30

Minimum Real Time Auxiliary Values

6

31

Minimum Demands

19

32

Programmable Min/Max Minimum Registers

16

33

Maximum Values Per Phase

33

34

Maximum Real Time Total Values

6

35

Maximum Real Time Auxiliary Values

6

36

Minimum Demands

19

37

Programmable Min/Max Maximum Registers

16

38

TOU System Parameters

2

39 ~ 46

TOU Energy #1 ~ #8

32

47 ~ 49

TOU Minimum Demands #1 ~ #3

16

50 ~ 52

TOU Maximum Demands #1 ~ #3

16

53 ~ 60

TOU Energy #9 ~ #16

32

<Ç¥ 2> EXTEND ÀÐÀ» Á¾·ùÀÇ µ¥ÀÌÅÍ ³»¿ë°ú Àбâ ÃÖ´ëÅ©±â

 

 

* Åë½Å ÇÁ·ÎÅäÄÝ º° ÀÐÀ» Á¾·ùº° ÀúÀå³»¿ë/À§Ä¡´Â ´ÙÀ½°ú °°´Ù.

 

             SATEC PM296 Åë½Å µå¶óÀ̺êÀÇ Àбâ/¾²±â Á¾·ùº° ÀúÀå³»¿ë°ú Ãâ·Â¹øÁö

 

 

¶ÇÇÑ <±×¸² 1> ÇÁ·ÎÅäÄÝ ¿É¼ÇºÎÀÇ  ¾ÆÀÌÄÜÀ» Ŭ¸¯Çϸé <±×¸² 2>ÀÇ ´ëÈ­»óÀÚ°¡ ³ªÅ¸³ª´Âµ¥ ¿©±â¼­µµ READ ½ºÄÉÁìÀ» ÀÛ¼ºÇÒ ¼ö ÀÖ´Ù.

 

<±×¸² 2> SATEC PM296 ÇÁ·ÎÅäÄÝ ÀÇ ¿É¼Ç ´ëÈ­»óÀÚ

 

<±×¸² 2>ÀÇ , ,  ¹öÅÏ°ú ¸®½ºÆ® ¹Ú½º¸¦ ÀÌ¿ëÇÏ¿© READ ½ºÄÉÁìÀ» ÀÛ¼ºÇÑ´Ù.

 

<±×¸² 3> SATEC PM296 ÇÁ·ÎÅäÄÝ ÀÇ READ Ãß°¡/ÆíÁý ´ëÈ­»óÀÚÀÇ ¿¹

 

 

<±×¸² 3>Àº <±×¸² 2>ÀÇ ÇÁ·ÎÅäÄÝ ¿É¼Ç ´ëÈ­»óÀÚ¿¡¼­ READ ½ºÄÉÁìÀ» Ãß°¡ ¶Ç´Â ÆíÁýÇÒ ¶§ ³ªÅ¸³ª´Â ´ëÈ­»óÀÚÀÌ´Ù.

 

 

 

2. ¾²±â ¼³Á¤

Ãâ·ÂÀº SCAN File°ú »ó°ü¾øÀÌ ÄÁÆ®·Ñ·¯ÀÇ Á÷Á¢ ADDRESS¿¡ ¾´´Ù.

 

µðÁöÅÐ Ãâ·Â ¼³Á¤¹ý

µðÁöÅÐ Ãâ·ÂÀ¸·Î Power Meter »óÅ °ª(reset µî)À» ¼³Á¤Çϰųª Relay µîÀ» Á¦¾îÇÒ ¼ö ÀÖ´Ù.

 

µðÁöÅÐ Ãâ·Â TAG ¼³Á¤ ½Ã ÇÊ¿äÇÑ ¿ä¼Ò

1) PORT           ¿¬°áµÈ PORT ¹øÈ£

2) STATION      ¸ÞŸÀÇ ID¹øÈ£. (1 ~ 247)

3) Address      Ãâ·Â ¹øÁö. 10Áø¼ö ¶Ç´Â 16Áø¼ö address ¹øÁö »ç¿ë (ÇÁ·ÎÅäÄÝ ¾²±â ³»¿ë ÂüÁ¶)

Ãâ·Â ¿µ¿ª(Extra1) ÀÌ DIRECT, VARIABLE : ½ÇÁ¦ Ãâ·Â Address¸¦ ÀÔ·Â.

±âŸ : °¢ Ãâ·Â¿µ¿ªÀÇ »ó´ë Address¸¦ ÀÔ·Â.

4) Extra1          Ãâ·ÂÇÏ°íÀÚ ÇÏ´Â ¿µ¿ª.

 

ALARM, AO_EXP, AO_SET, ASR, CLEAR, COMM1, COMM2, \nDATA_SET, DEFINE, DI, DIRECT, EVENT_FLG, LOG_SET, LOG_MEM, MAP, \nP_COUNT, PULSE, RELAY, RESET, RTC, SETUP, TIMER, USER_OP

 

ALARM : Alarm Setpoint Register ¾²±â,

AO_EXP : Analog Output Expander Setup ¾²±â,

AO_SET : Analog Output Setup ¾²±â,

ASR : Alarm Status Register ¾²±â,

CLEAR : Reset Energy/Maximum Demands,

COMM1 : Comm1 Communication Parameter ¾²±â,

COMM2 : Comm1 Communication Parameter ¾²±â,

DATA_SET : Data Log Setup ¾²±â,

DEFINE : User-Defined Data ¾²±â,

DI : Digital Inputs Allocation ¾²±â,

DIRECT : Direct MODBUS µ¥ÀÌÅÍ ¾²±â(Àý´ë MODBUS ¹øÁö¸¦ ÀÐÀ½) - Ãâ·Â °¡´É¿µ¿ª¸¸,

EVENT_FLG : User Event Flag1 ~ 8 ¾²±â (¾²±â Àü¿ë Registers),

EXTEND : Extend Data ¾²±â, Extend ¿µ¿ªº°·Î ±¸ºÐ(0~60 : <Ç¥ 2>ÂüÁ¶),

LOG_MEM : Log Memory Partitions Setup ¾²±â,

LOG_SET : Data Log Setup ¾²±â,

MAP : User Definable Register ¾²±â,

P_COUNT : Pulse Counters Setup ¾²±â,

PULSE : Pulse Setpoint ¾²±â,

RELAY : ¸±·¹ÀÌ »óÅ°ª(ON/OFF) º¯°æ ¾²±â,

RESET : Power Meter¸¦ Reset ½ÃÅ´ (address°¡ 0000 ÀÏ ¶§),

RTC : RTC Ãâ·Â (ÇöÀç½Ã°£),

TIMERS : Timers Setup ¾²±â,

USER_OP : User Selectable Option ¾²±â.

5) Extra2          Ãâ·Â¿µ¿ª ÀÌ PULSE ÀÏ ¶§ : Parameter ID 0 ~ 7 °ªÀ» ÀÔ·Â.

                        Ãâ·Â¿µ¿ª ÀÌ EXTEND ÀÏ ¶§ : 0 ~ 60, Extend ¿µ¿ª ÁöÁ¤. (<Ç¥ 2>ÂüÁ¶)

                        ±âŸ : »ç¿ë¾ÈÇÔ.

 

ÂüÁ¶)      SATEC PM296 Åë½Å µå¶óÀ̺êÀÇ ¾²±â Á¾·ùº° ÀúÀå³»¿ë/À§Ä¡

 

 

 

¿¹1) Station : 1  Address : 0000  Extra1 : CLEAR, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í µðÁöÅÐ Ãâ·ÂÀ» Çϸé 1¹ø Station Power MeterÀÇ Energy/Maximum Demands °ªÀÌ Reset(Clear) ½Ãų ¼ö ÀÖ´Ù.

 

¿¹2) Station : 1  Address : 0000  Extra1 : RELAY, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í µðÁöÅÐ Ãâ·ÂÀ» Çϸé 1¹ø Station Power MeterÀÇ 1¹ø(ù¹ø °) µðÁöÅÐ Relay¸¦ Á¦¾î(ON/OFF) ÇÒ ¼ö ÀÖ´Ù.

 

¿¹3) Station : 1  Address : 0001  Extra1 : RELAY, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í µðÁöÅÐ Ãâ·ÂÀ» Çϸé 1¹ø Station Power MeterÀÇ 2¹ø(µÎ¹ø °) µðÁöÅÐ Relay¸¦ Á¦¾î(ON/OFF) ÇÒ ¼ö ÀÖ´Ù.

 

¿¹3) Station : 1  Address : 0000  Extra1 : RESET, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í µðÁöÅÐ Ãâ·ÂÀ» Çϸé 1¹ø Station Power Meter¸¦ Àç ±âµ¿(Warm Start) ½Ãų ¼ö ÀÖ´Ù.

 

 

 

¾Æ³¯·Î±× Ãâ·Â ¼³Á¤¹ý

¾Æ³¯·Î±× Ãâ·ÂÀº BYTE/WORD/DWORD/FLOAT °ªÀ» ¸ÞŸ¿¡ ¾²´Â °ÍÀ» ¸»ÇÑ´Ù.

 

¾Æ³¯·Î±× Ãâ·Â TAG ¼³Á¤ ½Ã ÇÊ¿äÇÑ ¿ä¼Ò´Â µðÁöÅÐ Ãâ·ÂÅÂ±× ¼³Á¤¿ä¼Ò¿Í µ¿ÀÏÇÏ°í Ãâ·Â °ª¸¸ ´Ù¸£´Ù.

 

 

¿¹1) Station : 1  Address : 0001  Extra1 : SETUP, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í 5.5ÀÇ ¾Æ³¯·Î±× °ª(ASCII ÇÁ·ÎÅäÄÝÀÏ ¶§)À» Ãâ·ÂÇϸé 1¹ø Station Power MeterÀÇ PT °ªÀ» 5.1·Î º¯°æÇÒ ¼ö ÀÖ´Ù.

 

¿¹2) Station : 1  Address : 0002  Extra1 : SETUP, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í 100 ÀÇ ¾Æ³¯·Î±× °ªÀ» Ãâ·ÂÇϸé 1¹ø Station Power MeterÀÇ CT Primary Current °ªÀ» 100À¸·Î º¯°æÇÒ ¼ö ÀÖ´Ù.

 

¿¹3) Station : 2  Address : 0002  Extra1 : COMM, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í 1 ÀÇ ¾Æ³¯·Î±× °ªÀ» Ãâ·ÂÇϸé 1¹ø Station Power MeterÀÇ Address¸¦ 1¹øÀ¸·Î º¯°æÇÑ´Ù.

 

¿¹3) Station : 1  Address : 0003  Extra1 : COMM, EXTRA2 : ºóÄ­À¸·Î ¼³Á¤ÇÏ°í 7 ÀÇ ¾Æ³¯·Î±× °ªÀ» Ãâ·ÂÇϸé 1¹ø Station Power MeterÀÇ Åë½Å¼Óµµ¸¦ 19200bps·Î º¯°æÇÒ ¼ö ÀÖ´Ù.

 

 

 

3. Åë½ÅÄÉÀÌºí ¿¬°á ¹× Àü¿ø¿¬°á

 

 

RS-232C (COM1) Åë½ÅÄÉÀÌºí ¿¬°á¹ý

SATEC PM296 MeterÀÇ COM1 (9ÇÉ ´ÜÀÚ)¿¡ ÀÏ¹Ý RS-232C Åë½Å ÄÉÀ̺íÀ» ¿¬°áÇÑ´Ù. (¾à½Ä ¹è¼±À¸·Î ¿¬°áÇÏ¿©µµ µÊ)

 

 

RS-485(COM1) Åë½ÅÄÉÀÌºí ¿¬°á¹ý

SATEC PM296 MeterÀÇ +, ´ÜÀÚ´Â ÄÄÇ»ÅÍ ÃøÀÇ Rx+, Tx+ ¸¦ Short ½ÃÄÑ ¿¬°áÇÏ°í,

- ´ÜÀÚ´Â ÄÄÇ»ÅÍ ÃøÀÇ Rx-, Tx- ¸¦  Short ½ÃÄÑ ¿¬°áÇÑ´Ù.

 

 

ÄÄÇ»ÅÍ Ãø                                       SATEC PM296 Ãø

Tx+, Rx+  --------------------------------- +

Tx-, Rx-  --------------------------------- -

 

 

RS-422/485(COM2) Åë½ÅÄÉÀÌºí ¿¬°á¹ý

SATEC PM296 MeterÀÇ Tx+, Tx- ´ÜÀÚ´Â ÄÄÇ»ÅÍ ÃøÀÇ Rx+, Rx-¿¡ ¿¬°áÇÏ°í,

Rx+, Rx- ´ÜÀÚ´Â ÄÄÇ»ÅÍ ÃøÀÇ Tx+, Tx-¿¡ ¿¬°áÇÑ´Ù.

 

 

ÄÄÇ»ÅÍ Ãø                                    SATEC PM296 Ãø

Tx+  --------------------------------- Rx+

Tx-  --------------------------------- Rx-

Rx+  --------------------------------- Tx+

Rx-  --------------------------------- Tx-

 

 

 

±âº» Àü¿ø¿¬°á

SATEC RPT296ÀÇ 15, 16 ¹ø ´ÜÀÚ(<±×¸² 4> ÂüÁ¶>¿¡ Àü¿ø(95 ~ 250V, 45/65 HZ AC ¶Ç´Â 90 ~ 330 V DC)À» ¿¬°áÇÑ´Ù.

 

 

          <±×¸² 4> SATEC PM296 Power MeterÀÇ µÞ¸é

 

 

Meter Address, Åë½Å¼Óµµ ¼³Á¤

SATEC PM296 Power Meter ¾Õ¸é Á¶ÀÛ ½ºÀ§Ä¡(<±×¸² 5> ÂüÁ¶) ¶Ç´Â Åë½ÅÃâ·ÂÀ¸·Î Power Meter Address(1 ~ 247), Åë½Å¼Óµµ µîÀ» º¯°æÇÒ ¼ö ÀÖ´Ù.

 

          <±×¸² 5> SATEC PM296 Power Meter ÀÇ ¾Õ¸é